MAX-VSTP™ NEMA Premium® Efficiency Solid Shaft Vertical Motor
TECO-Westinghouse's MAX-VSTP™ Vertical Solid Shaft TEFC is a totally enclosed fan cooled motor built for deep well turbine pumps; irrigation; water/wastewater. Rated at 1.15 continuous service factor, this vertical motor operates on 460V, 3-phase, 60Hz power with NEMA Premium® Efficiency and Class F insulation. Construction is cast iron, finished in blue, and rated for 40 deg C ambient operation.
TECO-Westinghouse Vertical Motor, Model: MAX-VSTP™ Vertical Solid Shaft TEFC, 460V, 394 Amp (460V), 350 HP, 1800 rpm, 261.1 kW, 3-Phase, 60Hz, TEFC Motor Enclosure, 5009VP Frame, CCW Rotation, 1 Speed, Guide: Regreasable; Thrust: Spherical Roller Bearing, 4 Poles, Insulation Class: Class F, NEMA Premium® Efficiency Motor Efficiency Group, 96.2 % Efficiency, 1.15 Service Factor, 86.3 % Power Factor, P-Base Mounting, Solid Shaft, High Thrust, Cast Iron, Finish: Polyurethane Paint, Color: Blue, 40 deg C
| Amperage Rating |
: |
394 A |
| Bearing Type |
: |
Guide: Regreasable; Thrust: Spherical Roller |
| Color |
: |
Blue |
| Efficiency |
: |
96.2 % |
| Finish |
: |
Polyurethane Paint |
| Frame Size |
: |
5009VP |
| Frequency Rating |
: |
60 Hz |
| HP Rating |
: |
350 hp |
| Insulation Class |
: |
Class F |
| Material |
: |
Cast Iron |
| Model |
: |
MAX-VSTP™ Vertical Solid Shaft TEFC |
| Motor Efficiency Group |
: |
NEMA Premium® Efficiency |
| Motor Enclosure Type |
: |
TEFC |
| Mounting Type |
: |
P-Base |
| Number of Poles |
: |
4 |
| Number of Speeds |
: |
1 |
| Phase |
: |
3 ph |
| Power Factor |
: |
86.3 % |
| Power Rating |
: |
261.1 kW |
| Rotation Type |
: |
CCW |
| Service Factor |
: |
1.15 |
| Shaft Type |
: |
Solid Shaft |
| Speed Rating |
: |
1800 rpm |
| Temperature Rating |
: |
40 deg C |
| Thrust Rating |
: |
High Thrust |
| Voltage Rating |
: |
460 V |
- Output Range: 15 - 800 HP
- Speed: 1800, 1200 RPM
- Enclosure: Totally Enclosed Fan Cooled (IP55)
- Voltage: 230/460V (Usable on 208V); 150HP and Larger is 460V Only
- 230/460V Motors Suitable for Partial Winding Start (at 230V Only)
- Three Phase, 60 Hz, 1.15 Service Factor (Continuous on Sine Wave Power)
- CSA Certified for Class I, Div. 2, Group B, C, D - Temp Code T3 Minimum
- Inverter Duty (PWM) per NEMA® MG-1 Part 31 at 1.0 Service Factor
- Dual Column (60/50 Hz) Design Nameplate as Standard; 50 Hz Data 190/380V at 1.0 S.F.
- Standard Features: Non-Sparking Ball Type NRR, Drip/Splash Cover, Space Heaters (120V)
- 5000 Frames and Above also include Mounting Provisions for bearing RTD's and Insulated Bearing Housing
- CSA Certified for Class I, Div. 2, Groups B, C, D; Temp Code T3 minimum
- Class F Insulation with Phenolic Alkyd Resin Varnish
- Class B Temperature Rise
- NEMA Design B Torques
- Oversized Main Conduit Box Rotatable in 90 Degree Increments - Fully Gasketed with NPT Threaded Entrance
- Cast Iron Conduit Box for F#449TP and Below; Steel Plate Conduit Box for F#5000
- Designed for 40°C Ambient Temperature
- Designed for 3300 ft. Elevation
- Counterclockwise (CCW) Rotation; Viewed from Top
- Cast Iron Frame & End Brackets
- 1045 Solid Carbon Steel Shaft
- Aluminum Die Cast Squirrel Cage Rotor Construction
- Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
- Paint Color: Blue - Munsell 5PB 3/8
- Guide Bearings: 254VP - 286VP frames are Grease Pre-packed Double Shielded Bearings (MULTEMP SRL) 324VP - 5009VP frames are Re-Greasable (Mobil Polyrex EM)
- Thrust Bearings: 254VP - 286VP frames are Re-Greasable Angular Contact (Mobil Polyrex EM); 324VP - 449VP frames are Oil Lubricated Angular Contact; F#5000 and Above with Spherical Roller
- Oil Requirements for 324VP-405VP - 145 to 175 S.S.U. @100°F
- Oil Requirements for 444VP-5810VP - 300 S.S.U. @100°F
- Grounding Terminal Inside Main Box
- Stainless Steel Nameplate and Rodent Screens
- 12 Leads (PWS on 230V) on 254VP - 405VP; 6 Leads on 444VP to 449VP; 5000 Frames and Above with Connection Studs
- Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2 - 10:1 Variable Torque with NRR. 10:1 C.T., 20:1 VT without NRR Using Braking in VFD
- Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by VFD as stated per NEMA MG-1 Part 31
-
Specification Sheet
https://www.eindustrialsolutions.com//ASSETS/DOCUMENTS/ITEMS/EN/teco_max-vs_vss_tefc_spec_sheet.pdf
-
Owner's Manual